Express tests for determining the residual amount of β-lactams and tetracyclines in milk, whey

The kit is used to determine β-lactams and tetracyclines: penicillin G, cefkinoma, cloxacillin, cephalonium, amoxicillin, ceftiofur, oxacillin, cefapirin, nafcillin, cefoperazone, ampicillin, cefacetril, dicloxacillin, cefazolin, benzathine, tetracycline, doxycycline, chlortetracycline, oxymitetracycline , pasteurized, sterilized, reconstituted milk powder, milk whey, reconstituted milk whey.

 

  • PRODUCTS OF ANIMAL ORIGIN. Method for detecting residual amounts of beta-lactams and tetracyclines in milk, whey using test kits "PIONEER MEIZHENG BIO-TECH (2 in 1) JC0209

 

Test kit detection limit:

β-lactams

Limit of detection ppb (µg/L)

 

Cephalosporins

Limit of detection ppb (µg/L)

 

Penicillin G

1-2

Cefkin

5-7

Cloxacillin

3-6

Cephalonium

3-5

Amoxicillin

2-3

Ceftiofur

70-90

Oxacillin

5-7

Cefapirin

4-8

Nafcillin

7-10

Cefoperazone

3-5

Ampicillin

2-3

Cefacetril

15-20

Dicloxacillin

3-6

Cefazolin

20-30

benzathine

3-5

---

---

Tetracyclines

Limit of detection ppb (µg/L)

 

Tetracyclines

Limit of detection ppb (µg/L)

 

Tetracycline

7-10 _

Doxycycline

7-10

Chlortetracycline

7-10

Oxytetracycline

7-10

 

 

Set composition:

  • The kit includes everything you need for 96 definitions:
  • 12 tubes, each containing 1 strip with 8 wells with a reagent containing antibodies and 8 test strips;
  • 100 disposable Pasteur pipettes;
  • Instruction;
  • 8 wells with control reagent - Positive standard (antibiotic concentration is indicated on the packaging of the positive control and on the certificate of quality that comes with each lot of test kits);
  • 1 bottle of lyophilisate for negative control - Negative standard (does not contain antibiotics);
  • 1 well plate.

 

Sample preparation of milk and whey samples:
 
Powdered milk, powdered milk whey: Dissolve the sample in a suitable flask with warm distilled water (according to the current regulatory documentation), mix thoroughly.
 
Milk , reconstituted milk powder, reconstituted whey powder: Samples must be liquid and homogeneous. Samples should be free of clots and product separation phases. The temperature of the sample must be at least 4°C, neither frozen nor heated. Mix the sample thoroughly before testing.
 
 
The analysis can be carried out with or without an incubator.
 
        ◦ If using an incubator, place the sample well in a preheated 40°C incubator, pipette a 200 µl milk or whey sample and transfer to the reagent well from the kit. Thoroughly mix the sample with the reagent with a tenfold set and drain the liquid with a pipette in the well until a uniform pink color is obtained and incubate the mixture for 5 minutes.
Then place the test strip from the kit into the well with the reagent and sample and incubate in the incubator for another 5 minutes at 40°C.
 
        ◦ If an incubator is not available, the assay can be performed indoors at 16-25°C. Place the sample well in the well plate, pipette a 200 µl milk or whey sample and transfer to the well with the reagent from the kit. Thoroughly mix the sample with the reagent tenfold and drain the liquid with a pipette in the well until a uniform pink color is obtained. Incubate the mixture for 5 minutes.
Then place the test strip from the kit into the well with the reagent and sample and incubate in the incubator for another 5 minutes.
 
After incubation, remove the test strip from the reagent and sample well and interpret the result within 15 minutes. To save the result, remove both filters from both ends of the test strip.

Attached Files

Read together with it:

  • Roselkhoznadzor has identified violations in the declaration of meat products by a Perm producer
    Between April 2 and May 14, 2025, he issued veterinary accompanying documents for 48 kilograms of stewed pork. However, the declaration of conformity for these products did not contain evidence of their safety, including tests for the presence of antibiotics (chloramphenicol, tetracycline , etc.)bacitracin ), which are mandatory for canned meat. Products that did not pass the necessary tests were ...
  • TEST KIT for determination of inhibitory agents PIONEERPRODUKT® DASH-TEST, WC0040
    Test - set PIONEERPRODUKT® DASH - TEST Article No. WC 0040 Introduction PIONEERPRODUKT® DASH-TEST test kit is a microbiological test for the qualitative detection of residual quantities of antibiotics and inhibitory substances in raw (cow, goat, sheep), pasteurized, sterilized and pre-reconstituted milk powder . Principle The PIONEERPRODUKT® DASH-TEST test kit is based on a microbiolog...
  • Tests for antibiotics in milk - 10 interesting facts
    Testing for antibiotics in milk plays a key role in ensuring the safety and quality of dairy products. Here are 10 interesting facts about milk testing for antibiotics: 1. Tests for antibiotics in milk are carried out to detect the presence of traces of antibiotics that may enter the milk through the treatment of animals. 2. There are several methods for testing milk for antibiotics, including fer...
  • Antibiotics in beer: 10 interesting facts
    Antibiotics in beer: 10 interesting facts 1. Antibiotics are a group of medicines that are used to fight bacterial infections. However, they can also be used in beer production to prevent the development of diseases and ensure the safety of the drink. 2. During the beer production process, antibiotics can be used to control bacteria, yeasts and other microorganisms that can affect the quality and ...
  • Tests for antibiotics in milk, 10 interesting facts
    Tests for antibiotics in milk are an integral part of the quality and safety control system for dairy products. They allow you to detect the presence of antibiotics that may get into milk due to treatment of animals or errors in the processing process. These tests are carried out both in manufacturing plants and in laboratories, where specialists use various methods such as ELISA to accurately and...
  • Since the beginning of 2024, 18 declarations of conformity for products of animal origin have been invalidated in the Penza region.
    The basis for making the above decisions was the fact of false declaration – the absence of documentary evidence of the study of controlled products for all safety indicators stipulated by the requirements of the technical regulations of the Customs Union “On the safety of food products” (TR CU 021/2......
  • In Transbaikalia, declarations of conformity for products of animal origin were terminated in December
    The Rosselkhoznadzor Office for the Trans-Baikal Territory, as part of monitoring compliance with mandatory requirements, monitors declarations of conformity registered in the National System of Accreditation. In total, since the beginning of the year, 34 declarations of conformity for dairy and meat products have been terminated. When conducting a control (supervisory) event without interaction w...
  • Antibiotics in Milk
    Milk , as one of the key food products, plays an important role in the human diet. Recently, discussions around the antibiotic content of milk have become the subject of increased attention. In this article, we look at how antibiotics can get into milk , what risks this poses, and how the industry is combating this problem. 1. Use of antibiotics in agriculture: One of the main sources of antibioti...