TAGLER CLMN 1-8
MILK centrifuge with heating is a new generation centrifuge designed for determination of fat content in milk according to Gerber GOST R
iso 2446-2011 "Milk. Method for determination of fat content". Maintaining properties of popular milk centrifuges in
RUSSIA,
it has got new, very valuable additions:
TAGLER CLM 1-8 milk centrifuge is a centrifuge of a new generation; it is intended for determination of milk fat content according to GOST R ISO 2446-2011 "Milk. Method for determination of fat content".
Maintaining properties of popular milk centrifuges in Russia, it got new, very valuable additions:
The centrifuge's resistance to imbalance was increased - thanks to a modern motor mounting system;
This clamping system has also made the centrifuge virtually silent;
The control panel is simple and informative, thanks to modern digital technology;
The design and layout of the centrifuge has made it possible to reduce its size and make it very convenient to place in the workplace.
The smooth system of electronic braking of the rotor protects the butyrometers from shaking and the possibility of mixing and rejection of centrifugation results.
Centrifuge ZLMN 1-8 with heating is designed for separation of heterogeneous liquid systems with density up to 2 g/cm³ in the field of centrifugal forces. It is used in milk laboratories for determination of mass fraction of protein and fat and also for researches in physiology, biochemistry, veterinary medicine, microbiology, etc. The heating integrated in the centrifuge serves to reduce the temperature loss in the gipmeter during the centrifugation cycles, which provides more accurate readings. The presence of heating in the centrifuge does not mean that there is no water bath for Gerber analysis.
Smooth braking system for the rotor. Resistance to imbalance in differences between samples placed on the rotor - not more than 4 g.
Observation window on top lid allows the user to control the whole working process, user-friendly control buttons on the front panel and a display with the temperature on the heating element surface (not in the chamber) and the countdown of centrifugation time.
Technical parameters
Description
Maximum number of samples that can be placed on the rotor
8
Separation factor:
Relative centrifugal acceleration
350±50
Holding time range, min
1-90
Rated rotational speed of disk, min-1
1380
Power, W
180
Power supply voltage, V
220 ±10%
Frequency, Hz
50
Heating of the working chamber
Yes
Overall dimensions (LxWxH)
540x450x330
Weight, kg, not more
26